Grain Systems Bucket Elevtors, Conveyors, Series II Sweeps PNEG-1922 User Manual

Page 2

Advertising
background image

Page 2 of 5

PNEG-1922

Reverse Head/Take-Up Bridge Belt Conveyor Installation

3. Fasten the UHMW sheet to the head housing using six (6) 1/4"-20 x 3/4" button head socket cap

screw (or equivalent).

4. The UHMW take-up bridge will then go through the take-up and UNDER THE INTERMEDIATE

LINER using existing hardware.

(See Figure 2 below to

Figure 5 on Page 4.)

NOTE: Do not overtighten the hardware. Overtightening will pull the bolt heads through the liner(s).