10

TOPDRY

Prices and Specifications subject to change without notice. • 888-GSI-BINS • Fax 800-800-5329 • www.gsiag.com

April 4, 2011

Autoflow Series - Shelled Corn

(Metric Measurements)

Autoflow Series

7.32m Dia.

1-Fan

9.14m Dia.

1-Fan

9.14 Dia. 2-Fan

10.97 Dia.

1-Fan

10.97m Dia.

2-Fan

Fan &

Heater

Unit(s)

Plenum

Temper-

ature C°

Moisture

Content

Wet Basis

Bu/Hr

Dump

Interval

Min

Bu/Hr

Batch

Time

Hours

Bu/Hr

Batch

Time

Hours

Bu/Hr

Batch

Time

Hours

Bu/Hr

Batch

Time

Hours

11.19 kW

91.44 cm

1.125

Million

kCal

60

20%

13.4

21.6

14.1

31.9

23.9

18.9

25.2

25.8

25%

8.5

34.1

9.0

50.4

15.1

29.9

16.0

40.7

30%

5.3

54.6

5.6

80.8

9.4

47.9

10.0

65.2

71

20%

17.1

16.8*

18.1

24.9*

30.5

14.8

32.3

20.1

25%

10.9

26.6*

11.5

39.4*

19.3

23.4

20.4

31.8

30%

6.8

42.6*

7.2

63.1*

12.1

37.4

12.8

51.0

82

20%

20.1

14.4*

21.2

21.3*

35.7

12.6*

37.8

17.2*

25%

12.7

22.7*

13.4

33.6*

22.6

19.9*

24.0

27.2*

30%

8.0

36.4*

8.4

53.9*

14.1

32.0*

15.0

43.5*

11.19 kW

101.6 cm

1.125

Million

kCal

140

20%

16.5

17.5

18.1

25.0

29.3

15.4

32.2

20.2

25%

10.4

27.7

11.4

39.5

18.6

24.3

20.4

31.9

30%

6.5

44.4

7.1

63.3

11.6

39.0

12.8

51.1

160

20%

21.1*

13.7*

23.1*

19.5*

37.5

12.0

41.2

15.8

25%

13.3*

21.6*

14.6*

30.9*

23.8

19.0

26.1

24.9

30%

8.3*

34.7*

9.1*

49.5*

17.8

30.4

16.3

39.9

180

20%

24.7*

11.7*

27.1*

16.7*

43.9*

10.2*

48.3*

13.4*

25%

15.6*

18.5*

17.1*

26.4*

27.8*

16.2*

30.6*

21.3*

30%

9.8*

29.6*

10.7*

42.2*

17.4*

26.0*

19.1*

34.1*

22.37 kW

106.6 cm

1.125

Million

kCal

140

20%

18.8

15.4

20.5

22.0

20.8

31.3

36.9

17.6

25%

11.9

24.3

13.0

34.8

13.2

49.4

23.4

27.8

30%

7.4

38.9

8.1

55.8

8.2

79.1

14.6

44.6

160

20%

21.1

12.0

26.2

17.2

26.6

24.4

47.2

13.8

25%

15.2

19.0

16.6

27.2

16.9

38.6

29.9

21.7

30%

9.5

30.4

10.4

43.6

10.5

61.8

18.7

34.8

180

20%

28.2

10.2

30.7

14.7

31.2

20.8

55.3

11.7

25%

17.8

16.2

19.4

23.2

19.7

32.9

35.0

18.6

30%

11.2

25.9

12.1

37.2

12.3

52.8

21.9

29.8

29.83 kW

106.6 cm

2.5

Million

kCal

140

20%

23.4

19.3

24.1

26.9

25%

14.8

30.5

15.3

42.6

30%

9.2

48.9

9.6

68.2

160

20%

29.9

15.1

30.9

21.0

25%

18.9

23.8

19.6

33.3

30%

11.8

38.2

12.2

53.3

180

20%

35.0

12.9

36.2

18.0

25%

22.2

20.3

36.2

18.0

30%

13.8

32.6

14.3

45.5

* Insufficient burner BTUs for 45 deg. ambient temp

rating exclude loading time.

1/3 CFM/bu

cooling rate

Est. at temp 45 deg. F, rel. humidity 65%

Use only as a guide, conditions will vary capacities.

Advertising