9

TOPDRY

Prices and Specifications subject to change without notice. • 888-GSI-BINS • Fax 800-800-5329 • www.gsiag.com

April 4, 2011

Batch Series - Shelled Corn

(Metric Measurements)

Batch Series

7.32m Dia.

1-Fan

9.14m Dia.

1-Fan

9.14m Dia.

2-Fan

10.97 Dia.

1-Fan

10.97 Dia.

2-Fan

Fan &

Heater

Unit(s)

Plenum

Temper-

ature C°

Moisture

Content

Wet Basis

Bu/Hr

Batch

Time

Hours

Bu/Hr

Batch

Time

Hours

Bu/Hr

Batch

Time

Hours

Bu/Hr

Batch

Time

Hours

Bu/Hr

Batch

Time

Hours

11.19 kW

91.44 cm

1.125

Million

kCal

60

20%

10.1

2.5

11.7

3.3

18.5

1.9

13.2

4.1

21.4

2.6

25%

6.4

3.8

7.4

5.1

11.7

3.3

8.2

6.5

13.5

4.0

30%

4.0

6.1

4.6

8.2

7.2

5.2

5.2

10.4

8.5

6.5

71

20%

12.0

2.0

14.0

2.8

22.1

1.8

15.8

3.4

25.5

2.1

25%

7.6

3.2

8.8

4.4

14.0

2.7

10.0

5.4

16.2

3.4

30%

4.8

5.2

5.5

6.8

8.7

4.4

6.2

8.7

10.1

5.4

82

20%

15.4

1.6

17.2

2.4*

28.2

1.4

17.6

3.4*

32.6

1.6

25%

9.8

2.6

10.9

3.7*

17.9

2.1

11.2

5.2*

20.7

2.7

30%

6.1

4.0

6.8

6.0*

11.2

3.4

7.0

8.3*

12.9

4.2

11.19 kW

101.6 cm

1.125

Million

kCal

140

20%

12.3

2.0

14.3

2.4

16.5

3.3

25.9

2.1

25%

7.8

3.1

9.0

4.2

10.4

5.2

16.4

3.3

30%

4.9

4.9

5.6

6.7

6.5

8.4

10.3

5.3

160

20%

14.7

1.6

17.0

2.2

19.7

2.8

31.0

1.8

25%

9.3

2.6

10.8

3.5

12.5

4.4

19.6

2.8

30%

5.8

4.2

6.7

5.6

7.8

7.1

12.3

4.5

180

20%

18.9

1.3

21.8

1.8

22.6*

2.6*

39.6

1.4

25%

11.9

2.0

13.8

2.7

14.3*

4.1*

25.1

2.2

30%

7.5

3.3

8.6

4.4

8.9*

6.5*

15.7

3.5

22.37 kW

106.6 cm

1.125

Million

kCal

140

20%

16.2

2.4

18.2

2.9

29.0

1.9

25%

10.3

3.6

11.5

4.7

18.4

2.9

30%

6.4

5.9

7.2

7.5

11.5

4.7

160

20%

19.4

2.0

21.7

2.5

34.6

1.5

25%

12.3

3.1

13.8

4.0

21.9

2.5

30%

7.7

4.9

8.6

6.4

13.7

4.0

180

20%

24.8

1.5

27.2

2.0

44.3

1.3

25%

15.7

2.4

17.6

3.1

28.1

2.0

30%

9.8

3.9

11.0

4.9

17.5

3.2

29.83 kW

106.6 cm

2.5

Million

kCal

140

20%

18.5

2.1

20.6

2.7

25%

11.7

3.3

13.0

4.2

30%

7.3

5.2

8.1

6.7

160

20%

22.0

1.8

24.5

2.2

25%

13.9

2.7

15.5

3.5

30%

8.7

4.4

9.7

5.6

180

20%

28.2

1.4

31.4

1.8

25%

17.8

2.1

19.9

2.7

30%

11.2

3.4

12.4

4.4

* Insufficient burner BTUs for 45 deg. ambient temp

rating exclude loading time.

1/3 CFM/bu

cooling rate

Est. at temp 45 deg. F, rel. humidity 65%

Use only as a guide, conditions will vary capacities.

Advertising