Closed captioning, Closed captioning -23, Operating instructions – Cobalt Digital COMPASS 9068 Upconverter User Manual

Page 51: 9068 function submenu list and descriptions

Advertising
background image

9068-OM (V4.2)

9068 PRODUCT MANUAL

3-23

Operating Instructions

9068 Function Submenu List and Descriptions

Provides support for closed captioning setup.

Note:

When receiving HD-SDI, both CEA 608 and CEA 708 are supported, with CEA 608 and CEA 708 (containing CEA 608
packets) converted to line 21 closed captioning on outputs down-converted to SD (on up-convert of SD, only CEA 608
closed captioning is generated).

• Closed Captioning On/Off

Turns on or turns off the Closed Captioning output.

Note: • When set to On, closed captioning is set to standard default line

number. See Ancillary Data Line Number Locations and Ranges
(p. 3-8).

• Closed captioning line may contain active unintended data even if

closed captioning is set to Off. If closed captioning is not to be
used, it is recommended to use the Top Line Suppression
control to eliminate the possibility of this unintended data from
appearing in the active video area.
(See Scaler tab (p. 3-11) Top line suppression control for more
details.)

• Closed captioning On/Off will not remove existing packets unless

the Scaler is enabled. To remove packets without changing output
format, set Scaler to Enabled and HD:Convert to: to Same as
Input
. (See Scaler tab Top line suppression control for more
details.)

Closed Captioning

Table 3-2

9068 Function Submenu List — continued

Advertising