9985 function submenu list and descriptions – Cobalt Digital FUSION 3G 9985 3G_HD_SD Loudness Processor User Manual
Page 102
3
9985 Function Submenu List and Descriptions
3-50
9985 PRODUCT MANUAL
9985-OM (V1.18)
(continued)
• Short Term Window / Reset Control
Ganged Short Term Window control for Meter 1 and Meter 2 sets the
duration (in seconds) that sampling time accumulates before each
averaging recalculation (see below)
(0.1 to 60.0 seconds range in 0.1-second steps; default = 1.8 sec)
Reset button clears the accumulated moving average data, and restarts
measurement.
Table 3-2
9985 Function Submenu List — continued
t (sec)
In this example, the last 3 measurement periods are averaged in each reported LUFS value. This cycle is continually
repeated. The Measurement Window parameter sets the sampling time accumulated before each averaging recalculation.
Session
1st Report
2nd Report
3rd Report