Read cycle – Rainbow Electronics MAX7470 User Manual

Page 13

Advertising
background image

MAX7469/MAX7470

HDTV Continuously Variable

Anti-Aliasing Filters

______________________________________________________________________________________

13

write sequence must be repeated. Figures 6 and 7
show examples of write sequences.

Read Cycle

In read mode (R/W = 1), the MAX7469/MAX7470 write
the contents of the control/status or frequency registers
to the bus. When the command byte indicates a read
operation of either the control/status or the frequency
register, the serial interface expects an Sr condition to

follow the command byte. After sending an Sr, the mas-
ter sends the MAX7469/MAX7470 slave address byte
followed by a R/W bit (set to 1 to indicate a read). The
slave device (MAX7469/MAX7470) generates an ACK
for the second address word and immediately after the
ACK clock pulse, the direction of data flow reverses.
The slave (MAX7469/MAX7470) then transmits 1 byte of
data containing the value of the register that was

SDA

SCL

1

0

0

1

0

A1

A0

R/W

C7

C6

C5

C4

C3

C2

C1

C0

ACK

ACK

OUT

IN

OUT

IN TO MAX7469/MAX7470

SDA (CONT)

SDA

DIRECTION

SDA

DIRECTION

SCL (CONT)

F7

F6

F5

F4

F3

F2

F1

ACK

OUT

F0

IN

IN

START

STOP

0

0

0

1

0

0

1

0

COMMAND BYTE C7–C0 IS 0010010.

SDA

SDA

DIRECTION

SCL

1

0

0

1

0

A1

A0

R/W

C7

C6

C5

C0

ACK

ACK

OUT

IN

OUT

IN TO MAX7469/MAX7470

IN

START

STOP

0

0

0

0

0

0

0

0

C4

C3

C2

C1

THE COMMAND BYTE IS FOR POWER-DOWN.

Figure 6. Write Sequence to Update the Frequency Register

Figure 7. Write Sequence for a Command Byte

Advertising