Rainbow Electronics MAX7470 User Manual

Page 9

Advertising
background image

MAX7469/MAX7470

HDTV Continuously Variable

Anti-Aliasing Filters

_______________________________________________________________________________________

9

MAX7469 when driving an ADC or video decoder with an
input range the same as the input to the MAX7469. For
added flexibility, the MAX7469 accepts input signals with
twice the standard video-signal range, which can be
used for driving an ADC or video decoder with an input
signal range that accepts a larger signal swing. The
MAX7470 can also be used to drive an ADC or video
decoder when a gain of two is desired.

Output Clamp Level

The MAX7469/MAX7470 output can be DC- or AC-
coupled. The nominal output clamp level in the
DC-coupled case depends on the clamp voltage set-
ting and can be determined according to Table 2.

As shown in the

Sync Detector and Clamp Settings

section, the low clamp level is used for signals with
sync information and determines the voltage level of the
sync tip, while the high clamp level is used for signals
without sync information and sets the blanking level.

The absolute voltage level of the output signal is rela-
tive to the output clamp level. A video signal containing
sync information (i.e., CVBS or Y) is unipolar above the
clamp level and conversely, a video signal without sync
(i.e., P

b

P

r

or C) is bipolar around the clamp level.

Power-Down Mode

The MAX7469/MAX7470 include a power-down mode
that reduces the supply current from 180mA (typ) to 1mA
(typ) by powering down the analog circuitry. The I

2

C

interface remains active, allowing the device to return to
full-power operation. The clamp settling time (see the

Electrical Characteristics

section) limits the wake-up time

of the MAX7469/MAX7470. After exiting the power-down
mode, the MAX7469/MAX7470 resume normal operation
using the settings stored prior to power-down. The
power-down and wake-up modes are controlled through
the command byte (see Table 3). A software reset sets
the control/status register to its default conditions, but
the frequency register is not affected.

Power-On Reset (POR)

The MAX7469/MAX7470 include a POR circuit that
resets the internal registers and I

2

C interface to their

default conditions (see Tables 4, 5, and 6).

Serial Interface

The MAX7469/MAX7470 feature an I

2

C-compatible, 2-wire

serial interface consisting of a bidirectional serial-data line
(SDA) and a serial-clock line (SCL). SDA and SCL facilitate
bidirectional communication between the MAX7469/
MAX7470 and the master at rates up to 400kHz.

The MAX7469/MAX7470 have a command interpreter
that is accessed by writing a valid command byte.
Once a command byte is written to the MAX7469/
MAX7470, the command interpreter updates the con-
trol/status register accordingly. See the

Control/Status

Register

section for more information. The command

interpreter also controls access to the frequency regis-
ter through a command byte (see the

Command Byte

(

Write Cycle)

section).

The MAX7469/MAX7470 are transmit/receive slave-only
devices, relying upon a master to generate a clock sig-
nal. The master (typically a µC) initiates data transfer on
the bus and generates SCL.

A master device communicates to the MAX7469/
MAX7470 by transmitting the proper address (see the

Slave Address

section) followed by a command and/or

data words. Each transmit sequence is framed with a
START (S) or REPEATED START (Sr) condition and a
STOP (P) condition.

The SDA driver is an open-drain output, requiring a
pullup resistor (2.4kΩ or greater) to generate a logic-
high voltage. Optional resistors (24Ω) in series with
SDA and SCL protect the device inputs from high-volt-
age spikes on the bus lines. Series resistors also mini-
mize crosstalk and undershoot of the bus signals.

Bit Transfer

Each SCL rising edge transfers 1 data bit. Nine clock
cycles are required to transfer the data into or out of the
MAX7469/MAX7470. The data on SDA must remain stable
during the high period of the SCL clock pulse. Changes in
SDA while SCL is high are read as control signals (see the

START and STOP Conditions

section). When the serial

interface is inactive, SDA and SCL idle high.

Table 2. Output Clamp Level

CLAMP SETTING

OUTPUT CLAMP LEVEL (V)

Low

1.0 (typ)

High

1.6 (typ)

Advertising