MAX9218

27-Bit, 3MHz-to-35MHz
DC-Balanced LVDS Deserializer

14

______________________________________________________________________________________

ESD Protection

The MAX9218 ESD tolerance is rated for the Human
Body Model and ISO 10605. ISO 10605 specifies ESD
tolerance for electronic systems. The Human Body

Model discharge components are C

S

= 100pF and R

D

= 1.5k

Ω (Figure 14). The ISO 10605 discharge compo-

nents are C

S

= 330pF and R

D

= 2k

Ω (Figure 15).

Chip Information

TRANSISTOR COUNT: 17,782

PROCESS: CMOS

STORAGE
CAPACITOR

HIGH-

VOLTAGE

DC

SOURCE

DEVICE

UNDER

TEST

CHARGE-CURRENT-

LIMIT RESISTOR

DISCHARGE

RESISTANCE

1M

R

D

1.5k

C

S

100pF

STORAGE
CAPACITOR

HIGH-

VOLTAGE

DC

SOURCE

DEVICE

UNDER

TEST

CHARGE-CURRENT-

LIMIT RESISTOR

DISCHARGE

RESISTANCE

50

Ω TO 100Ω

R

D

2k

C

S

330pF

Figure 14. Human Body ESD Test Circuit

Figure 15. ISO 10605 Contact Discharge ESD Test Circuit

Advertising