DS2172

031197 5/20

PIN

DESCRIPTION

TYPE

SYMBOL

24

RL

I

Receive Load. A positive–going edge loads the previous 32 bits of data
received at RDATA into the Pattern Receive Registers. RL is logically OR’ed
with control bit PCR.3. Should be tied to V

SS

if not used.

25

RDATA

I

Receive Data. Received NRZ serial data, sampled on the rising edge of
RCLK.

26

RDIS

I

Receive Disable. Set high to prevent the data at RDATA from being
sampled. Set low to allow bits at RDATA to be sampled. Should be tied to V

SS

if not used. See Figure 6 for timing information. All receive side operations
are disabled when RDIS is high.

27

RCLK

I

Receive Clock. Input clock from transmission link. 0 to 52 MHz. Can be a
gapped clock. Fully independent from TCLK.

28

V

DD

Positive Supply. 5.0 volts.

29

V

SS

Signal Ground. 0.0 volts. Should be tied to local ground plane.

30

TCLK

I

Transmit Clock. Transmit demand clock. 0 to 52 MHz. Can be a gapped
clock. Fully independent of RCLK.

31

TDIS

I

Transmit Disable. Set high to hold the current bit being transmitted at
TDATA. Set low to allow the next bit to appear at TDATA. Should be tied to
V

SS

if not used. See Figure 7 for timing information. All transmit side opera-

tions are disabled when TDIS is high.

32

TDATA

O

Transmit Data. Transmit NRZ serial data, updated on the rising edge of
TCLK.