Rainbow Electronics DS2172 User Manual

Page 8

Advertising
background image

DS2172

031197 8/20

PT3 PTR.3

Polynomial Tap Bit 3.

PT2 PTR.2

Polynomial Tap Bit 2.

PT1 PTR.1

Polynomial Tap Bit 1.

PT0 PTR.0

Polynomial Tap Bit 0.

6.0 PATTERN CONTROL REGISTER

The Pattern Control Register (PCR) is used to configure
the operating parameters of the DS2172 and to control

the patterns being generated and received. Also the
PCR is used to control the pattern synchronizer and the
error and bit counters.

PCR: PATTERN CONTROL REGISTER (Address=06 Hex)

(MSB)

(LSB)

TL

QRSS

PS

LC

RL

SYNCE

RESYNC

LPBK

SYMBOL

POSITION

NAME AND DESCRIPTION

TL

PCR.7

Transmit Load. A low to high transition loads the pattern generator with
the contents of the Pattern Set Registers. PCR.7 is logically ORed with the
input pin TL. Must be cleared and set again for subsequent loads.

QRSS

PCR.6

Zero Suppression Select. Forces a “one” into the pattern whenever the
next 14 bit positions are all “zeros”. Should only be set when using the
QRSS pattern.
0 = Zero suppression disabled
1 = Zero suppression enabled

PS

PCR.5

Pattern Select.
0 = Repetitive Pattern
1 = Pseudorandom Pattern

LC

PCR.4

Latch Count Registers. A low to high transition latches the bit and error
counts into the user accessible registers BCR and BECR and clears the
internal register count. PCR.4 is logically OR’ed with input pin LC. Must be
cleared and set again for subsequent loads.

RL

PCR.3

Receive Data Load. A transition from low to high loads the previous 32 bits
of data received at RDATA into the Pattern Receive Registers (PRR).
PCR.3 is logically OR’ed with input pin RL. Must be cleared and set again
for subsequent latches.

SYNCE

PCR.2

SYNC Enable.
0 = auto resync is enabled.
1 = auto resync is disabled.

RESYNC

PCR.1

Initiate Manual Resync Process. A low to high transition will force the
DS2172 to resynchronize to the incoming pattern at RDATA. Must be
cleared and set again for a subsequent resync.

LPBK

PCR.0

Transmit/Receive Loopback Select. When enabled, the RDATA input is
disabled; TDATA continues to output data as normal. See Figure 1.
0 = loopback disabled
1 = loopback enabled