Ds1875 pon triplexer and sfp controller – Rainbow Electronics DS1875 User Manual
Page 58

DS1875
PON Triplexer and SFP Controller
58
______________________________________________________________________________________
Table 01h, Register F8h: ALARM
3
POWER-ON
VALUE
00h
READ
ACCESS All
WRITE
ACCESS
PW1
MEMORY
TYPE Volatile
F8h
TEMP HI
TEMP LO
VCC HI
VCC LO
MON1 HI
MON1 LO
MON2 HI
MON2 LO
BIT
7
BIT
0
Layout is identical to ALARM
3
in Lower Memory, Register 70h with two exceptions.
1. VCC LO alarm is not set at power-on.
2. These bits are latched. They are cleared by power-down or a write with PW1 access.
Table 01h, Register F9h: ALARM
2
POWER-ON
VALUE
00h
READ
ACCESS
All
WRITE
ACCESS
PW1
MEMORY
TYPE
Volatile
F9h
MON3 HI
MON3 LO
MON4 HI
MON4 LO
RESERVED
RESERVED
RESERVED
RESERVED
BIT
7
BIT
0
Layout is identical to ALARM
2
in Lower Memory, Register 71h with one exception.
1. These bits are latched. They are cleared by power-down or a write with PW1 access.