Ds1875 pon triplexer and sfp controller – Rainbow Electronics DS1875 User Manual
Page 64

DS1875
PON Triplexer and SFP Controller
64
______________________________________________________________________________________
Table 02h, Register 85h: M4DAC
FACTORY
DEFAULT
00h
READ
ACCESS PW2
WRITE ACCESS
PW2 and M4DAC EN = 0
MEMORY TYPE
Volatile
85h 2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
BIT
7
BIT
0
The digital value used for M4DAC and recalled from Table 06h at the adjusted memory address found in
VINDEX. This register is updated at the end of the MON4 conversion.
V
M4DAC
=
2.5
256
(M4DAC
+1)
Table 02h, Register 86h: DEVICE ID
FACTORY
DEFAULT
75h
READ
ACCESS PW2
WRITE
ACCESS N/A
MEMORY
TYPE ROM
86h
0 1 1 1 0 1 0 1
BIT
7
BIT
0
Hardwired connections to show the device ID.
Table 02h, Register 87h: DEVICE VER
FACTORY
DEFAULT
DEVICE
VERSION
READ
ACCESS PW2
WRITE
ACCESS N/A
MEMORY
TYPE ROM
87h DEVICE
VERSION
BIT
7
BIT
0
Hardwired connections to show device version.