Ds1875, Pon triplexer and sfp controller – Rainbow Electronics DS1875 User Manual
Page 81
Advertising

DS1875
Table 02h, Register C1h to C2h: RESERVED
FACTORY
DEFAULT
00h
READ
ACCESS PW2
WRITE
ACCESS PW2
MEMORY
TYPE Nonvolatile
(SEE)
These registers are reserved.
Table 02h, Register C3h: M3QT DAC
FACTORY
DEFAULT
00h
READ
ACCESS PW2
WRITE
ACCESS PW2
MEMORY TYPE
Nonvolatile (SEE)
C3h 2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
BIT
7
BIT
0
Register to control M3QT DAC.
V
M3QT
=
1.25
256
M3QT DAC
+1
(
)
Table 02h, Register C4h: DAC1
FACTORY
DEFAULT
00h
READ
ACCESS PW2
WRITE
ACCESS PW2
MEMORY TYPE
Nonvolatile (SEE)
C4h 2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
BIT
7
BIT
0
Register to control DAC1.
V
DACI
=
2.5
256
DAC1
+1
(
)
PON Triplexer and SFP Controller
______________________________________________________________________________________
81
Advertising