______________________________________________________________________________________

Table 02h, Register BCh: HTXP

FACTORY

DEFAULT

00h

READ

ACCESS PW2

WRITE

ACCESS PW2

MEMORY TYPE

Nonvolatile (SEE)

BCh 2

7

2

6

2

5

2

4

2

3

2

2

2

1

2

0

BIT

7

BIT

0

Fast comparison DAC threshold adjust for high TXP. This value is added to the APC DAC value recalled from
Table 04h. If the sum is greater than 0xFF, 0xFF is used. Comparisons greater than V

HTXP

, compared against

V

BMD

, create a TXP HI alarm. The same ranging applied to the APC DAC should be used here.

V

HTXP

=

Full Scale

255

 HTXP

+ APC DAC

(

)

Table 02h, Register BDh: LTXP

FACTORY

DEFAULT

00h

READ

ACCESS PW2

WRITE

ACCESS PW2

MEMORY

TYPE Nonvolatile

(SEE)

BDh 2

7

2

6

2

5

2

4

2

3

2

2

2

1

2

0

BIT

7

BIT

0

Fast-comparison DAC threshold adjust for low TXP. This value is subtracted from the APC DAC value recalled
from Table 04h. If the difference is less than 0x00, 0x00 is used. Comparisons less than V

LTXP

, compared

against V

BMD

, create a TXP LO alarm. The same ranging applied to the APC DAC should be used here.

V

LTXP

=

Full Scale

255

 APC DAC  LTXP

(

)