Installation to Wood Stud Wall

NOTE: This step is for mounting enclosure assembly (A) flush against supporting surface. For use with

mount, follow instructions provided with wall mount.
Use a stud finder to locate the edges of the studs and draw a vertical line down each stud’s center. Place enclosure

assembly (

A) on wall as a template, level and mark the center of the six mounting holes. Make sure that the

mounting holes are on the stud centerlines. Drill six 5/32" (4 mm) dia. holes 2.5" (64 mm) deep. Make sure that the

enclosure is level and secure it using six 2.5" wood screws (

C) and six washers (E) as shown in figure 3.1.

NotE: If cord cover plate assembly (K) is used on the rear of the enclosure, you may use the 1/2" spacer (M)

between enclosure assembly and wall surface.
Skip to step 4.

• DO NOT lift more weight than you can handle. Always use an assistant or mechanical lifting equipment to safely lift

and position enclosure assembly (

A).

• Installer must verify that the supporting surface will safely support the combined load of the equipment and all

attached hardware and components.

• Tighten wood screws so that the enclosure assembly is firmly attached, but do not overtighten. Overtightening can

damage the screws, greatly reducing their holding power.

• Never tighten in excess of 80 in. • lbs. (9 N.M.).
• Make sure that mounting screws are anchored into the center of the stud. The use of an "edge to edge" stud finder

is highly recommended.

• Hardware provided is for attachment of mount through standard thickness drywall or plaster into wood studs.

Installers are responsible to provide hardware for other types of mounting situations.