Approved Optics
www.ApprovedOptics.com
J9144A-A
X2-LRM 10GB Module
1310nm, 220m, MMF, SC RoHS6
DOM Parameters
Parameter
Values
Unit
Min.
typ.
Max
Laser Bias Current Monitor Accuracy
(2)
-10
+10
%
Transmit Power Monitor Accuracy
(3)
-3
3
dB
Receive Power Monitor Accuracy
(3)
-3
3
dB
1) 0 to 70°C case temperature.
2) 0 to 12.5 mA.
3) -8.2 dBm to +0.5 dBm.
Parameter
Symbol
Values
Unit
min.
typ.
max.
Module Retention Force (latch strength)
FRET
200
N
Module Insertion Force
FIN
40
N
Module Extraction Force (with kick-out)
FEXT-K
16
N
Module Extraction Force (without kick-out)
FEXT
25
N
Eye Safety
This laser based multimode transceiver is a Class 1 product. It complies with IEC 60825-
1 Ed.2: 2007 and FDA performance standards for laser products (21 CFR 1040.10 and
1040.11) except for deviations pursuant to Laser Notice 50, dated June 24, 2007.