Neutrik NPPA-TT-S PATCH PANEL “Easy Patch” User Manual

Page 7

Advertising
background image

Page 7 of 13

NPPA-TT-S Instruction Manual

4. Grounding variations


The flexible grounding system provides the following versions:

Individual:

Each channel is individually grounded by its corresponding cable shield
(default configuration).

Group:

Selected channel grounds are connected via the ground bus on the
PCB using solder bridges and track cuts to form a group that is
connected to one common cable shield.

Central:

All channel grounds (individual top and bottom row) are connected via
the ground bus on the PCB using solder bridges and wired with only
one cable shield.

Chassis-Common:

The same as central grounding but with the addition of the common
ground bus (top and / or bottom rows) connected to the patch panel
chassis by means of jumpers.