Durafire, Oil igniter, Specifications – Forney DURAFire User Manual

Page 2: Hesi specifications

Advertising
background image

Pub # 404006-04

Rev 11/2011

DURAFire

®

Oil Igniter

Specifications

Fuel:

No. 2 oil

BTU Rating:

6-30 MBtu/hr

Atomization Media:

Air

Fuel Pressure:

60 psig (at igniter)

Atomizing Air Pressure:

80 psig (at igniter)

Cooling / Combustion Air:

Flow: 60 SCFM (at igniter)
Pressure Drop: Approximately 3 in. WC across device

Length:

Available in 2 inch increments from 24 to 180 inches (609 to 4572 mm)

Outside Diameter:

4” (igniter can be installed in an existing mount tube for a 4” diameter device)

Material of Construction:

Guide Tube and Mount Tube - Carbon Steel
Furnance End of Guide Tube - 304 Stainless Steel
Oil Tip Assembly - 304 Stainless Steel

Retraction Assembly

Per Customer Requirments

Oil Tip Assembly

Narrow or Wide angle, as required

HESI Specifications

Input Voltage:

120 to 240 VAC, 50/60 Hz

Input Power:

120 VAC @ 1.5 A (2-A fuse); 240 VAC @ 0.75A (1-A fuse)

Output Voltage:

2000 VDC

Output Energy:

12 joules per spark

Spark Rate:

3 per second (approximately)

Duty Cycle:

50% at temp 0°F to 135°F (-18°C to 57°C) Ambient

HESI

Air

Inlet

Oil

Inlet

Cooling/

Combustion

Air

Guide Tube

Primary

Combustion

Zone

“V” Band

Retainer

Forney Corporation • 3405 Wiley Post Road • Carrollton, TX 75006 • 800-356-7740 • Fax 972-458-6650 • www.forneycorp.com

DuraFire_rev11-2011.indd 2

11/15/2011 3:47:40 PM

Advertising