Forney Digital Profile Detector (DPD) User Manual
Page 2
Forney Corporation
3405 Wiley Post Road
Carrollton, TX 75006 USA
Tel: 972.458.6100
Fax: 972.458.6650
www.forneycorp.com
TECHNICAL BULLETIN
PUBLICATION
#404005-02
REV 11/08
DIGITAL PROFILE DETECTOR
FL
AME DETECTORS
THE SUPER-BLUE DIGITAL PROFILE DETECTOR
Front Mount:
Part #7819506
Tangential Unit:
Part #39089301
THE CLASSIC DIGITAL PROFILE DETECTOR
Front Mount:
Part #7819504
Tangential Unit:
Part #39089201
SPECIFICATIONS
Mounting:
1” NPT sight pipe fitting
3/8” NPT purge air fitting
Material:
Die-cast aluminum housing with matte black, anti-slip
finish
Electrical:
24 VDC (available from associated Forney Amplifier)
Current Rating:
60mA
Temperature: Super-Blue:
-4°F to +131°F
-20°C to +55°C
Classic:
-4°F to +150°F
-20°C to +65°C
Humidity: 0-95%
Rh-Non-condensing
Weight:
2.4 Lbs. (1.1 Kg)
Cooling Air:
10 SCFM@6” WC (15 SCFM@10” WC with fiber optics)
Approvals:
Factory Mutual, CE (Consult factory for system
configuration)
Sensor/Wavelength:
Super-Blue Model – Super-blue silicon cell / 290 - 390 nm
Classic Model – Lead sulfide cell / 700-2,500 nm