Factory Direct Hardware Hansgrohe 18020001 User Manual

Page 2

Advertising
background image

2

Axor Massaud Single-Control Highriser Lavatory Faucet

18020XX1

Product Specification

Max. Flow Rate 2.2 gpm

Max. incoming water pressure

145 psi

Recommended water pressure

14.5 - 72 psi

Max. hot water temperature

176

o

F*

Recommended hot water temp

120

o

F - 140

o

F*

Hole size in mounting surface

1 3/8”

Max. mounting surface thickness

1 5/8”

10 mm supply hoses -- 10 mm - 3/8” adapters included.

No drain or pull rod is included.

This faucet may be used with a continuous flow water heater

if the flow pressure is at least 20 psi.

*Know and follow all applicable local plumbing codes when setting the tem-

perature on the water heater. In Massachusetts, the water heater may be set no

higher than 112

o

F.

Do not allow the supply hoses to bend

or twist!

Advertising