Factory Direct Hardware Von Duprin 9847EOF3 User Manual

Installation instructions, Von duprin, Series mortise exit device

Advertising
background image

Installation Instructions

®

98/9975

Series Mortise Exit Device

This product is covered by the

following patent numbers:

3,767,238 4,427,223
3,854,763 4,466,643
4,167,280 4,741,563

911374_00(3) © 2006 Ingersoll-Rand Company Limited

Devices covered by these instructions:

98/9975 Mortise Exit Device

98/9975-F (Fire) Mortise Exit Device

CD98/9975 (Cylinder Dogging) Mortise Exit Device

EL98/9975 (Electric Latch Retraction) Mortise Exit Device

98/9975-2 (Double Cylinder) Mortise Exit Device

911374-00

CUT DEVICE

1

Measure amount to cut off device.

8

Special tools needed:
#10-24 tap
#12-24 tap
Drill bits: #25, 1/8”, 1/4”,

5/16”, 13/32”

Index:

• Screw chart ................................... 2
• Preparation chart ......................... 3
• Device installation ................... 4-5
• Optional equipment ................ 6-7
• Cut device ..................................... 8

VON DUPRIN

®

9

2

Tape and mark area being cut.

Tape

Cover plate

(flush to pushbar)

Pushbar

Remove anti-rattle clip

If 5/8” diameter wire access hole

has been predrilled in door, cut

device 5/16” from center of hole.

Note

5/16”

Cut device square

and remove all

burrs

3

Cut device square.

NOTE: Device must

be cut square for

proper end cap fit

4

Slide anti-rattle clip into device

.

Anti-rattle

clip

2”

Minimum

1-1/2” minimum clearance

(with endcap removed)

Device aligned

with mounting

holes

Please give these instructions to building owner after device is installed