Installation Instructions

6221 Electric Strike

®

4. Test strike: Apply solenoid power. Fail secure (FSE) lip unlocks.

Fail safe (FS) lip locks.

5. Install strike with two #12-24 screws. Make sure clearance

between latch bolt and strike lip is 1/32” (Figure 2). If not,

uninstall strike, adjust (Figure 3), and reinstall.

6. Test door: With strike unlocked, door opens with latch bolt

extended. When door closes, latch bolt rides over strike lip.

931224_00(5) Copyright © 2004 Ingersoll-Rand. All rights reserved.

89/336/EEC

Notes: Deadbolt will not function with this strike.

Check with factory for retrofit applications.

1. For lock or device preparation, see their directions.

2. Prepare door for strike (see other side).

3. Wire strike (Figure 1).

Double Door Open Back Mortise or Cylindrical Application

Figure 1

Yellow solenoid wires = 12 VDC, 0.57 A

Black solenoid wires = 24 VDC, 0.29 A

(also shown on strike label)

SOLENOID POWER REQUIREMENTS

DC input is

nonpolarized.

NOTE

!

J1

P1

P1 J1A

P1A

SO-12 or SO-24

12 VDC

or

24 VDC

12 VAC SO-12 12 VDC
or
24 VAC SO-24 24 VDC

{
{

Wiring

for DC

supply

Wiring
for AC

supply

Solenoid

Use crimp

connectors to

splice field wiring

to P1 leads

Figure 2

Top view;

faceplate not

shown for clarity

1/32”

Latch bolt

Strike lip

Figure 3

To adjust strike,
loosen screws A, B,
and C and move
backbox sideways
as necessary

A

B

C

931224_5

931224_5

931224_5

931224_5

931224_5

PREPUBLICA

TION

REVIEW COPY REV. A

931224-00