Factory Direct Hardware Hansgrohe 38117 User Manual
Page 4
Advertising

4
Install the new cup washers and springs in the rough.
Install the cartridge assembly.
Installation with 38111181 rough manufactured after 04/2004
Remove the covers from the plaster shields.
Trim the plaster shields so that they extend 1/16”
outside the surface of the finished wall. Seal the wall
around the plaster shield with waterproof sealant.
Use a 17 mm socket wrench to remove the spout plug.
Use a 7 mm socket wrench to remove the cartridge
housing. Remove and discard the flush insert.
Turn the water off at the supply before
beginning this installation.
1.
2.
Advertising
This manual is related to the following products: