Adjust rods, Warning, Caution – Factory Direct Hardware Von Duprin 9947WDCEOF User Manual

Page 3: Attention, Give these instructions to building owner

Advertising
background image

Install bottom adjusting screw through bottom rod

(Figure 2).

With top latch bolt still retracted,

adjust bottom rod so latch bolt

clears floor and bottom strike.

Turn bottom locking screw in. Do not

over-tighten.

ADJUST RODS

Open door and release top latch bolt as shown

(Figure 1).

Loosen bottom locking screw (Figure 2).

Disconnect bottom vertical rod by

removing bottom adjusting screw.

Loosen top locking screw.

Rotate top adjusting screw clockwise until top latch bolt

is fully extended (Figure 1).

Check top latch bolt for deadlocking (latch bolt should

not push in).

Turn top locking screw in. Do not

over-tighten.

Depress pushbar and release.

Make sure top latch bolt stays retracted as shown.

1.

2.
3.

4.
5.

6.

7.

8.
9.

10.

11.

12.

Latch bolt retracted

(flush with latch case)

Check device operation by opening and closing door

several times from the outside.

Redo adjustment procedure if :

- Top latch bolt is not held retracted

- Bottom latch bolt does not clear

floor and bottom strike

13.

Bottom

latch bolt

(clears floor

and strike)

Figure 3

Figure 4

Figure 1

Top latch bolt

Shown fully extended

Figure 2

Bottom

adjusting

screw

Top

locking

screw

Top

adjusting

screw

Bottom

locking

screw

3

10

This product is not intended to detain or prevent exit,

but to delay egress for not more than 15 seconds in

accordance with NFPA 101 requirements for “special

locking arrangements”.

The signal switch inside the device is pre-set at the factory. Tampering with

this switch can cause the basic exit features of this device to fail in an

emergency.

There are no user serviceable parts in the electronic

module or in the delay mechanism. Consult factory

for repair of these components.

1. The electronic delay module is located in a separate

box and must be installed by an electrician.

2. Check door size carefully before cutting device and

cover. refer to back page of instruction for dimensions.

3. Device should be tested periodically for proper

function and moving parts should be lubricated

semiannually.

**Give these instructions to building owner**

NOTE TO

OWNER

WARNING

!

CAUTION

!

ATTENTION!