Pivot the lever upwards to turn the water on. Pivot it to
the right for cooler water, to the left for warmer water.
Pivot the lever downwards to turn the water off.
Pull out on the diverter knob to divert the water to the
handshower. When the water is turned off, the diverter
will reset to the spout position.
The handshower incorporates the Rubit
TM
cleaning system.
If scale deposits are noticed in the spray channels, rub
across the channels with a finger or a sponge to dislodge
them.
Troubleshooting
Problem
Possible Cause
Solution
Insufficient water
Screen washer dirty
Remove and clean screen washer
Check valve faulty
Replace check valve
Handle hard to move
Cartridge dirty or faulty
Replace cartridge
Faucet drips
Cartridge dirty or faulty
Replace cartridge
Water not hot enough
High temperature limit stop set
incorrectly
Reset high temperature limit stop