SHUT OFF WATER SUPPLIES.

Consider the type and thickness of your

finished wall before placing your stringer

back plate. Install the body (1) so the

surface of the finished wall is flush with the

front of the plasterguard (2) ± 3/8".

Note:

For models with stops (3), plasterguard

MultiChoice

®

Rough-In Installation

1

A.

B.

Distance (1) from the stringer (2) to the

front of the plasterguard is 2.8" (71 mm).

Distance (3) from the stringer (2) to the

front of the bonnet is 3.9" (99 mm).

must be flush or subflush 3/8" to

finished wall. Mount body using the two

stringer mounting holes (4) on the bracket.

Note: Remove cover (5) to access

mounting holes. Make sure the word

“UP” (6) is on top of the valve body when

installing.

If a thin wall is used, be sure to have the

plasterguard behind the wall, otherwise

the wall should always be flush with the

front of the plasterguard. See instruction

on the bag for thin wall mounting.

1

2

6

5

4

4

1

3

2

3