3 rs232 communication parameter – SENA HD132x Series User Manual

Page 32

Advertising
background image

HD132x Series User Manual

32

Server & Client Mode

This is when the HelloDevice operates as TCP server AND client. If you are to transmit data from a

serial device to a remote server through the HelloDevice, it will operate as a TCP client. If TCP

connection is requested by a remote client, it will operate as TCP server.

Note:

TCP mode can not be changed during RS232 data transmission.

[HD Port]

[HD Port] is the port number of the HelloDevice for TCP connection in TCP Server mode. The range is

2000 ~ 65535.

[Server IP, Server PORT]

When your HelloDevice is set to TCP Client mode, you need to specify the IP address and the port

number of a remote server that is to communicate with the HelloDevice. The range [PORT] is 2000 ~

65535.

(3) [Notifier]

Data server means the server that administers information of the HelloDevice. This is only when [IP

mode] of the HelloDevice is set to Dynamic IP mode AND the environment requires TCP server

function (DHCP, TCP server). since the IP address keeps changing every 24-hour in Dynamic IP

mode, there is a need for a data center to administer the IP address and other information of the

HelloDevice. To configure a data center, the UDP server socket program which administers setup

information that is periodically transmitted from the PC and the HelloDevice, must be running. (Refer

to Section 5.3)

The HelloDevice sends its IP address and other information to the data server according at an interval

set in [Time Interval]. The range of [Time Interval] is from 90 seconds to 6 hours.

4.4.3 RS232 Communication Parameter

This section describes how to set parameters of the HelloDevice for RS232 communication.

Select [Serial] windows for setting system parameters. (Figure 4.19)

[Baud]

150, 300, 600, 900, 1200, 2000, 2400, 3600, 4800, 7200, 9600, 19200, 38400

[Parity]

One of None, Even, Odd

Advertising