Session recall – Universal Audio Apollo Software User Manual

Page 54

Advertising
background image

Apollo Software Manual

Chapter 3: Console Application

54

Monitor Level

This is the master level control for Apollo’s monitor outputs; it performs the same func-
tion as the MONITOR knob on Apollo’s front panel.
The specific monitor output level is displayed in decibels beneath the Monitor Level con-
trol. The relative monitor output is indicated by the green LED ring surrounding the Level
control, like the MONITOR knob on Apollo’s front panel. When the monitor outputs are
muted, the ring is red.

Apollo Twin

When the Monitor function is selected (via the Monitor Select
button), the Monitor Level knob has a dot in its center. The
dot is green when the monitor outputs are not muted, and red
when the monitor outputs are muted, as shown at right.
The colored dots provide a visual indication in Console of the
monitor outputs mute state when the Preamp function is selected. Because the knob on
Apollo Twin serves multiple functions, the monitor outputs state cannot always be viewed
via the front panel.

Session Recall

Overview

The Recall controls provide a method for managing complete
Console configurations as session (preset) files. When a Con-
sole session file is saved, the current Console configuration is
written to disk. When a session file is subsequently reloaded,
Console is returned to the exact same configuration state,
regardless of any changes to Console that were made in the
interim.
Content of Session Files
Console session files contain most, but not all, Console settings. The specific parameters
are listed below.

Parameters Saved in Session Files

All knob, slider, and menu values, all inserted UAD plug-ins, settings contained within
the plug-ins, and settings in Console Settings window (except those listed below).

Parameters Not Saved in Session Files

All Monitor Gain, Line Output Reference Levels, Clock Source, Sample Rate, and Monitor
Outputs Digital Mirror settings are global parameters that are not session-specific. These
settings are in the Console Settings window.
The Unit Tab Monitor/Expander designation when multi-unit cascading is also not saved
in session files.