3 power supply, 4 connectors, 3 power supply 2.4 connectors – GE Industrial Solutions 6KCV300DVN User Manual
Page 13
6KCV300DVN
2
13
——————
HARDWARE DESCRIPTION
——————
Switch 8 Switch 7 Baud Rate
OFF
OFF
125 kBaud
OFF
ON
250 kBaud
ON
OFF
500 kBaud
ON
ON
125 KBaud
DN21
5.
The dip switch S1 determines the Slave address. The address “0” is reserved
to the Master and it must not be used. The switches S1 -7 and S1-8 do not
determine any address. The address is detected only when the board is
switched on. If the address is modified, the Drive has to be switched off
and then switched on in order to assume the new address.
6.
Connect the Bus cable to the BUS connection terminal.
7.
Switch on the drive.
8.
The LEDS PWR and RUN light up.
9.
Switch the Device Net power supply on; the LED H1 lights up.
10. The LED OP lights up when the Master/Slave connection has been
established.
2.3 POWER SUPPLY
The power supply is provided by the XO connector, which is used to connect
the data between the 6KCV300DVN board and the Drive regulation board.
Absorbed current: 350 mA
2.4 CONNECTORS
Connector
:
It allows to connect the ground (GNDE) of the
external power supply to the ground (PE).
Connector XS
It allows to connect the ground (PE) to the
DeviceNet cable shield.
Terminal BUS
See the figure below. It allows to connect the
6KCV300DVN board to the DeviceNet network.
The pins are the following: