background image

5-28

Chapter 5: RAID configuration

3.

When prompted, use the arrow keys to select

Yes from the Consistency Check?

dialog box then press <Enter>.

A progress bar appears on screen showing the progress of the consistency check.

4.

While checking the disk consistency, press <Esc> to display the following options.

• Stop

- Stops the consistency check. The utility stores the percentage of disk

checked. If you restart the consistency check, it will continue from the
percentage it stopped and continues the checking with the remaining
percentage that is not yet checked.

• Continue - Continues the consistency check.

• Abort

- Aborts the consistency check. When you restart checking, it starts from

zero percent.

5.

When checking is complete, press any key to continue.

SPACE-(De)Select, F10-Initialize

LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010

BIOS Version A.10.09231523R

Select VD(s)

Configure

Initialize

Objects

Rebuild

Check Consistency

Management Menu

Easy Configuration - ARRAY SELECTION MENU

Virtual Drive(s) Configured

LD RAID Size #Stripes StripSz Status

0 10 154494MB 2 64KB ONLINE

Virtual Drive 0

Virtual Drives

Yes

No

Consistency Check?

SPACE-(De)Select, F10-Initialize

LSI Software RAID Configuration Utility Ver C.05 Oct 26,2011

BIOS Version A.11.02090932R

The Data On The Drives Is Inconsistency. Repair Done!

Configure

Initialize

Objects

Rebuild

Check Consistency

Management Menu

Easy Configuration - ARRAY SELECTION MENU

Virtual Drive(s) Configured

LD RAID Size #Stripes StripSz Status

0 10 154494MB 2 64KB ONLINE

Virtual Drive 0

Virtual Drives

CC Under Process

VD 0 Consistency Check. Press Esc to Abort.

85% Completed