5 checking the drives for data consistency, Checking the drives for data consistency -19, Using the check consistency command – Asus Z9NH-D12 User Manual

Page 131

Advertising
background image

ASUS Z9NH-D12 Series

5-19

5.2.5

Checking the drives for data consistency

You can check and verify the accuracy of data redundancy in the selected virtual

drive. The utility can automatically detect and/or detect and correct any differences

in data redundancy depending on the selected option in the Objects > Adapter

menu.

The Check Consistency command is available only for virtual drives included

in a RAID 1 or RAID 10 set.

Using the Check Consistency Command

To check data consistency using the Check Consistency command
1. From the Management Menu, select Check Consistency, and then press

<Enter>.

2. The screen displays the available RAID set(s) and prompts you to select

the virtual drive to check. Press <Space> to select the virtual drive from the

Virtual Drive sub-menu, and then press <F10>.

Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option

LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010

BIOS Version A.10.09231523R

CC of VD(s)

Configure

Initialize

Objects

Rebuild

Check Consistency

Management Menu

SPACE-(De)Select, F10-Initialize

LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010

BIOS Version A.10.09231523R

Select VD

Configure

Initialize

Objects

Rebuild

Check Consistency

Management Menu

Easy Configuration - ARRAY SELECTION MENU

Virtual Drive(s) Configured

LD RAID Size #Stripes StripSz Status

0 1 148.580GB 2 64KB ONLINE

Virtual Drive 0

Virtual Drives

Advertising
This manual is related to the following products: