8 enabling writecache, Enabling writecache -24, 24 chapter 5: raid configuration – Asus Z9NH-D12 User Manual

Page 136

Advertising
background image

5-24

Chapter 5: RAID configuration

5.2.8

Enabling WriteCache

You may manually enable the RAID controller’s WriteCache option after creating a

RAID set to improve the data transmission performance.

When you enable WriteCache, you may lose data when a power interruption occurs

while transmitting or exchanging data among the drives.

The WriteCache function is recommended for RAID 1 and RAID 10 sets.

To enable WriteCache
1. From the Management Menu, select Objects > Adapter, select an existing

adapter, and then press <Enter> to display the adapter properties.

2. Select Disk WC, and then press <Enter> to turn on the option.

5. When finished, press any key to continue.

3. From the Management Menu, select Objects > Virtual Drive, select an

existing adapter and press <Enter>. Select View/Update Parameters and

press <Enter> to display the adapter properties.

4. Select Disk WC, and then press <Enter> to turn on the option.

Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option

LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010

BIOS Version A.10.09231523R

Disk Write Cache - Off(Write Through or On(Write Back)

Configure

Initialize

Objects

Rebuild

Check Consistency

Management Menu

Adapter

Virtual Drive

Physical Drive

Objects

Rebuild Rate = 30

Chk Const Rate = 30

FGI Rate = 30

BGI Rate = 30

Disk WC = Off

Read Ahead = On

Bios State = Enable

Cont On Error = Yes

Fast Init = Enable

Auto Rebuild = On

Auto Resume = Enable

Disk Coercion = 1GB

Factory Default

Adapter 0

Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option

LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010

BIOS Version A.10.09231523R

Disk Write Cache Setting of VD

Configure

Initialize

Objects

Rebuild

Check Consistency

Management Menu

Adapter

Virtual Drive

Physical Drive

Objects

RAID = 0

Size = 148.580GB

Stripe Size = 64KB

#Stripes = 2

State = OPTIMAL

Spans = 1

Disk WC = On

Read Ahead = On

Virtual Drive

Advertising