Function Switch. This switch controls the power supply to the unit and built-in infrared illuminator.

The switch has three positions:
1) OFF position — the unit is off.
2) ON position — the unit is on (IIT powered). Turn the unit on by turning the switch from OFF to ON.
3) IR position — the unit is on, and the IR illuminator is activated. Activate the IR illuminator by turning

the switch from ON to the IR position.
lens Focus. This control focuses the objective lens. Adjust the lens for the clearest, sharpest image.
Diopter Adjustment. This control focuses the eyepiece. Use it to get the clearest image possible on

the IIT screen.
IR Activity Indicator. A PERMANENT RED GLOW in the eyepiece viewing area indicates that the IR il-

luminator is operating.
low battery Indicator. A FLASHING RED LIGHT in the eyepiece viewing area indicates that the battery

is low.

TESTIng PROcEDuRES

cAuTIOn:

Do not test the scope in daylight conditions for more than 10 minutes, even with the protective

lens cap on.

To perform an operational check in daylight or in an illuminated room, follow these steps:
1) Verify that the battery is inserted into the battery compartment in accordance with polarity mark-

ings on the monocular’s body.
2) Verify that the objective lens is securely closed.
3) without removing the protective lens cap, activate the unit. While looking through the eyepiece of

your unit, observe the scene. Verify that the green light indicating correct IIT operation is illuminated.

FOcuSIng

To focus your Avenger Monocular, perform the following steps:

1) Adjust the diopter. Turn the diopter adjustment ring clockwise until it stops. While looking through

the eyepiece, observe the scene and slowly begin turning the diopter adjustment ring counterclock-

wise until the image becomes clear and sharp.

2) Adjust the lens’ focus. To focus your monocular at different distances, rotate the objective lens.

OPERATIOn In nIgHTTIME cOnDITIOnS

cAuTIOn:

Avoid exposing the night vision device to bright light sources. Bright light emitted by fires,

automobile headlights, lanterns, projectors, etc. will damage your Avenger.

1) Visually estimate the illuminance level in the viewing area. Operation of the device with the objective

lens cap removed is safe when the illuminance level is less than 1 lux; at an illuminance level of 1 lux,

you will barely be able to read a newspaper, even after your eyes have adapted to the low level of light.
2) Verify that the battery is inserted into the battery compartment in accordance with the polarity

markings on the monocular’s body.
3) Remove the front lens cap.
4) Activate the unit. After a momentary delay, green light indicating correct IIT operation will appear.

Advertising