Operational checks, After checking procedures – Armasight NSGNYX7001GGDA1 Nyx7 GEN 3+ Ghost Night Vision Goggles User Manual

Page 25

Advertising
background image

25

SEq NO.

LOCATION ITEM TO

CHECK/SERVICE

PROCEDURE

NOT FULLY MISSION

CAPABLE IF...

4

Lens Cap

Inspect for cracked, torn, or missing lens caps.

Cap is torn or cut.
Cup is not secured to the housing

of the lens.

5

Eyecups

Inspect for dirt or dust. Inspect for cracked, torn, bent,

broken or improperly fitted eyecup.
If necessary, clean as per Part 4.4.2.

Cup is torn or cut.

6

Battery

Compartment/ Cap

Inspect for corrosion, moisture, corroded or defective

contacts. Verify that the o-ring is present.

Contacts are damaged or corroded,

or the o-ring is missing.

7

Lenses

Inspect optical surfaces for dirt, fingerprint residue,

scratches, chips, or cracks.

Scratches or chips hinder vision

when the Nyx-7 is turned on. Cracks

are present.

8

Focusing Ring

Rotate the focusing ring to ensure free movement (range

is approximately 1/3 turn).

Ring gets stuck or adversely affects

the user’s ability to properly focus

the unit.

9

Eyepiece Rings

Rotate the eyepiece rings to make sure the eyepiece is not

too tight or too loose. Range is approximately ½ turn.

Ring gets stuck, is too loose, or ad-

versely affects the user’s ability to

properly adjust the diopter.

10

Goggle Kit

Check the straps and pads for cuts tears, fraying, holes,

cracks or defective fasteners.
Check the mount of goggle kit for dirt, dust or corrosion.

Insert goggle rail into guide to verify secure attachment

of goggle to head mount. If necessary, clean the mount

with water.
Press the buttons of the mount and check for free motion.

Inspect for damage.

11

Optional Equip-

ment

Inspect optional items for dirt, or corrosion, damage, and

missing parts. Check for proper operation.
If necessary, clean as detailed in Part 4.4.2.

Equipment is damaged or parts are

missing.

OPERATIONAL CHECKS

CAUTION:
Do not activate the Nyx-7 in daylight unless the lens cap is on, or you are operating under dark conditions.
NOTE:
Daylight checks are described below.

12

Operating
Button

Install the battery. Push the button by short press. Look

for the green glow in eyepieces (it should appear after a

slight delay).

Image is present.

Push the button by long press for activate the buily-in IR

illuminator. Look for a permanent red glow in the eye-

piece viewing area.

Permanent red glow is absent

13

Viewed Image

Inspect for any operational defects (refer to Part 4.3: Iden-

tification of Operational Defects).

Shading, edge glow, flashing, flick-

ering, and intermittent operation,

or excessive cosmetic defects are

found.

AFTER CHECKING PROCEDURES

14

Turn the unit OFF. Verify that the green glow fades from

the eyepieces.
Remove the battery.
Return the unit and all accessories to the soft carrying

case.