4 maintenance – Armasight NSGNYX7001GGDA1 Nyx7 GEN 3+ Ghost Night Vision Goggles User Manual

Page 29

Advertising
background image

29

4.4 MAINTENANCE

4.4.1 GENERAL

The section regarding Nyx-7 operator maintenance consists of operational tests, inspections for unit

serviceability, cleaning and mounting procedures, troubleshooting, and replacement instructions for

a limited number of parts. Maintenance instructions covered elsewhere in this manual (PMCS, trouble-

shooting, etc.) are not repeated in this section.

CAUTION:

The Nyx-7 is a precision electron-optical instrument, and must be handled carefully at all times

to prevent damage to the device’s body or mechanisms.

4.4.2 CLEANING PROCEDURES

CAUTION:

Thoroughly dry each item before placing them into the storage case.

Clean the Nyx-7 as follows:
1. Gently brush off any dirt from the unit’s body using a clean, soft cloth.
2. Moisten the cloth with fresh water and gently wipe down external surfaces (except for glass sur-

faces).
3. Dry any wet surfaces (except for glass surfaces) with another clean, soft, dry cloth.
4. Using a lens brush, carefully remove all loose dirt from the glass surfaces.
5. Slightly dampen a cotton swab with ethanol. Gently and slowly wipe the lenses. Without touching

the lens holders, clean the glass surfaces in circular movements, beginning in the center and moving

out towards the edge. Change the cotton swab after each circular stroke. Repeat until the glass surfaces

are clean.
6. Clean the battery contact surfaces and contact springs with a pencil eraser and/ or alcohol-damp-

ened cotton swabs.
Clean optional mounting devices with a soft brush (cloth), soap, and water as required.
Clean optional lenses as detailed in items 4 and 5 above (except for the demist shield).

4.4.3 BATTERY REMOVAL AND REPLACEMENT

Refer to Part 3.1.1 for battery installation procedures. No special tools are required to replace the bat-

tery.

Advertising