B. INTENSIFIER TUBE REPLACEMENT MANUAL

The intensifier tube can be removed or installed without disassembling the unit’s wired housing. Re-

moving or installing the intensifier tube only requires the removal of the eyepiece. The airtight seal

will be broken, and the final assembly must be purged with nitrogen to eliminate moisture within the

Goggles.

B.1 INITIAL SETUP

A. Test Facility

Clean station in the electronic repair service area.
B. Tools

None
C. Materials/Parts

Intensifier Tube

Cotton-tipped applicators

Isopropyl alcohol