PARAMETER SYMBOL
MIN
TYP
MAX
UNIT
CONDITIONS
Over-temperature Protection
Thermal Overload Trip
Temperature (h)
T
JT
150 175
°C
Thermal hysteresis (h)
10
°C
Note:
(h)
Over-temperature protection is designed to prevent device destruction under fault conditions.
Fault conditions are considered as “outside” normal operating range, so this part is not designed