Absolute maximum ratings, Recommended operating conditions – Diodes 74HC125 User Manual

Page 3

Advertising
background image

74HC125

Document number: DS35326 Rev. 3 - 2

3 of 9

www.diodes.com

January 2013

© Diodes Incorporated

74HC125



Absolute Maximum Ratings

(Note 4) (@T

A

= +25°C, unless otherwise specified.)

Symbol

Description

Rating

Unit

ESD HBM

Human Body Model ESD Protection

2

KV

ESD CDM

Charged Device Model ESD Protection

1

KV

ESD MM

Machine Model ESD Protection

200

V

V

CC

Supply Voltage Range

-0.5 to +7.0

V

V

I

Input Voltage Range note 3)

-0.5 to +7.0

V

I

IK

Input Clamp Current V

I

< -0.5V or Vi > V

CC

+0.5V

±20 mA

I

OK

Output Clamp Current V

O

< -0.5V or V

O

> V

CC

+0.5V

±20

mA

I

O

Continuous Output Current -0.5V < V

O

V

CC

+0.5V

+/- 25

mA

I

CC

Continuous Current Through V

CC

50 mA

I

GND

Continuous Current Through GND

-50

mA

T

J

Operating Junction Temperature

-40 to +150

°C

T

STG

Storage Temperature

-65 to +150

°C

P

TOT

Total Power Dissipation

500

mW

Notes:

4. Stresses beyond the absolute maximum may result in immediate failure or reduced reliability. These are stress values and device operation should

be within recommend values.

5. Input Voltage cannot exceed V

CC

to the extent the Maximum clamp current is exceeded.



Recommended Operating Conditions

(Note 6) (@T

A

= +25°C, unless otherwise specified.)

Symbol Parameter

Conditions Min

Max

Unit

V

CC

Supply Voltage

2.0 6.0 V

V

I

Input Voltage

0

V

CC

V

V

O

Output Voltage

0

V

CC

V

Δt/ΔV

Input Transition Rise or Fall Rate

V

CC

= 2.0V

625

ns/V

V

CC

= 4.5V

140

V

CC

= 6.0V

85

T

A

Operating Free-Air Temperature

-40 +125 °C

Note: 6. Unused inputs should be held at V

CC

or Ground.




























Advertising