Parameter measurement information – Diodes 74HC125 User Manual

Page 5

Advertising
background image

74HC125

Document number: DS35326 Rev. 3 - 2

5 of 9

www.diodes.com

January 2013

© Diodes Incorporated

74HC125


Parameter Measurement Information

V

CC

Inputs

V

M

V

LOAD

C

L

R

L

V∆

V

I

t

r

/t

f

2.0V to 6.0V

V

CC

≤3ns

V

CC

/2

2 X V

CC

15,50 pF

2 KΩ

10% of V

CC

Voltage Waveform

Pulse Duration

Voltage Waveform

Propagation Delay Times

Figure 1 Load Circuit and Voltage Waveforms


Notes: A. Includes test lead and test apparatus capacitance.

B. All pulses are supplied at pulse repetition rate ≤ 1 MHz.

C. The inputs are measured one at a time with one transition per measurement.

D. For the 3 state device t

PLZ

and t

PZL

are the same as t

PD

.

E. t

PZL

is measured at V

M

.

D. t

PLZ

is measured at V

OL

+V

.

















TEST Condition

t

PLZ

(see Notes D and E)

t

PZL

(see Notes D and F)

Vload
Vload