FIGURE 10F – COVER INSTALLATION

16. If the shafts are not horizontal, or coupling

is to be used vertically, assemble cover
halves with the lug and match mark UP or
on the high side. Push gaskets in until
they stop against the seals and secure
cover halves with fasteners, tightening to
torque specified in Figure 10H. Ensure

gaskets stay in position during fastener
tightening.

FIGURE 10G – COVER INSTALLATION,

VERTICAL POSITION

17. Ensure the lube plugs are installed in the

cover.

WARNING: Coupling Failure

Do not operate coupling without proper lubrication

Failure to follow these instructions could result in
serious personal injury or death and property
damage.

Tightening Torque
Values

Size

Parallel

Offset

(P)

Angular

(x-y)

Hub Gap
+/- 10%

End Float

Physical

Limit (Min)

2xF

Cover Fastener

Tightening Torque

Values

Flange

Type

31 & 35

Maximum

Allow able

RPM

Lube Wt.

Max Inch Max Inch

Inch

Inch

In. Series

Fasteners

(lb*in)

In. Series

Fasteners

(lb*in)

lb

1040T

0.006

0.003

0.125

0.211

100

120

3600

0.12

1050T

0.008

0.004

0.125

0.212

200

250

3600

0.15

1060T

0.008

0.005

0.125

0.258

200

440

3600

0.19

1070T

0.008

0.005

0.125

0.259

200

440

1800

0.25

1080T

0.008

0.006

0.125

0.288

200

825

1800

0.38

Installation Limits

FIGURE 10H – MISALIGNMENT & FASTENER TORQUE VALUES

13