Parallel alignment angular alignment – Xylem 8100 Series Centrifugal Pumps AC2515 REV.C User Manual

Page 14

Advertising
background image

Final Alignment
Final alignment cannot be accomplished until
the pump has been operated initially for a
sufficient length of time to attain operating
temperature. When normal operating
temperature has been attained, secure the
pump to re-check alignment and compensate
for temperature accordingly. See Alignment
Section.

WARNING: Rotating Components
Hazard

Do not operate pump without all guards in place.
Failure to follow these instructions could result in
serious personal injury or death and property
damage.

WARNING: Coupling Failure

Do not operate pump with coupling out of
alignment. Ensure final coupling alignment is
within the values stated above or according to the
coupling manufacturer’s instructions. Coupling,
pump, or driver failure may occur.

Failure to follow these instructions could result in
serious personal injury or death and property
damage.

OPTIONAL Alignment Procedure
If desired, the pump and motor feet can be
doweled to the base after final alignment is
complete. This should not be done until the
unit has been run for a sufficient length of
time and alignment is within the tolerance.
See Doweling Section.

CAUTION: Extreme Temperature and/or
Flying Debris Hazard

Eye protection and gloves required. Failure to
follow these instructions could result in property
damage and/or moderate personal injury.

NOTE: Pump may have been doweled to
base at factory.

DOWELING
Pump units may, if desired, be dowelled on
diagonally opposite feet. This should not be done
until the unit has been run for a sufficient length of
time and alignment is within the above alignment
tolerance.

DIAL INDICATOR

REFERENCE

MARK

SEPARATORS TO

TAKE UP BEARING

SLACK

PARALLEL ALIGNMENT

ANGULAR ALIGNMENT

FIGURE 11 – CHECKING ALIGNMENT (METHOD 2)