Appendix “c” field test report – Xylem 8100 Series Centrifugal Pumps AC2515 REV.C User Manual

Page 62

Advertising
background image

APPENDIX “C” FIELD TEST REPORT

USEFUL FORMULAS

1) Head (ft.) =

S.G.

2.31

x

(psig.)

Pressure

S.G. = specific gravity ;

S.G. of water = 1.0 at 70°F

2) TDH (ft.) = Total Dynamic Head (ft.) = (Disch. pressure gauge reading - Suct. pressure gauge reading) +

(Discharge velocity head - Suction velocity head) +

(Elevation correction to disch. gauge - Elevation correction to suct. gauge)

3) PUMP INPUT HP (BHP) - calculated:

Single Phase Motor

Three Phase Motor

BHP

=

746

p.f.

x

n

x

x Volts

Amps

m

BHP

=

746

p.f.

x

n

x

1.732

x

x Volts

Amps

Avg.

m

where

n

m

= motor efficiency, p.f. = motor power factor, Avg. Amps =

3

3

leg

2

leg

1

leg





4) Pump Efficiency (n

p

):

n

p

=

BHP

x

3960

TDH

x

GPM

5) Affinity Laws for correcting GPM, TDH, and BHP for speed (RPM):

2

1

GPM

GPM

=

2

1

RPM

RPM

or

GPM

1

= GPM

2

x

2

1

RPM

RPM

2

1

TDH

TDH

=

(

2

1

RPM

RPM

)

2

or TDH

1

= TDH

2

x

(

2

1

RPM

RPM

)

2

2

1

BHP

BHP

=

(

2

1

RPM

RPM

)

3

or BHP

1

= BHP

P

2

x

(

2

1

RPM

RPM

)

3

6) NPSHA

DETERMINATION:

NPSHA = Net Positive Suction Head Available

NPSHA = (Atmospheric pressure - Vapor pressure of liquid + Total suction head)

Total Suction Head = (Suction pressure gauge reading + Suction velocity head + Elevation correction to

suction gauge)

NOTE: NPSHA must always be greater than NPSHR (NPSHA > NPSHR) for the pump to operate without

concern of cavitation.

NPSHR refers to Net Positive Suction Head Required by pump. This is a published value obtained from
the Pump Manufacturer’s curve.

2 of 2