FIGURE 52 – OILER ASSEMBLY

1. Remove the vent assembly from the top of

the bearing housing.

2. Remove the pipe plug from the bottom of

the bearing housing.

3. Loosen the thumb screw on the side of the

oiler. Lift and remove the reservoir.

4. Flush the oiler and bearing housing with a

light grade of oil. Flush until all foreign
particles have been removed.

5. Screw the pipe plug and vent assembly

back into place.

6. Using the predetermined heights from

Table 1, set the level adjuster mechanism.

7. Place the level adjuster back in the lower

casting.

“A” Dimension

8100 Pump Size

Inboard Outboard

8X8X17, 10X8X12,
10X8X17, 10X10X12,
12X10X12, 12X10X14,
12X10X17, 10X8X20,
12X10X18

1.22

0.53

6X4X10, 8X6X13,
6X4X11, 8X6X10,
8X6X17, 8X6X18,
8X6X12M, 8X8X12

.053

0.56

3X2X11, 6X4X9,
6X4X12, 6X4X14,
6X6X9, 8X6X9,
8X6X12

1.12

1.12

TABLE 1 – LEVEL ADJUSTER HEIGHTS

8. Fill the reservoir with a food grade of

filtered mineral oil. Refer to oil lubrication
instructions given previously in this
manual for type of oil.

RESERVOIR

VENT
ASSEMBLY

THUMB
SCREW

BEARING
HOUSING

NOTE: You must fill through Trico reservoir.

LEVEL
ADJUSTER
MECHANISM

9. Back out the thumb screw on the side of

the lower casting so it will not interfere
when setting the reservoir in the lower
casting.

LOWER
CASING

10. Place thumb over reservoir spout, invert

and place reservoir on lower casting while
removing thumb. Allow reservoir to empty,
filling the bearing housing. Several fillings
of the reservoir may be required before
the actual level is reached. When the oil
level is reached, no more oil will run out of
the reservoir.

PIPE
PLUG

11. Retighten thumb screw.

After the pump has been started, trial
adjustments should be made to the level
adjuster mechanism to prevent too high or
too low of oil levels. Adjust by repeating steps
6 through 11.

A periodic filling of the reservoir is required.
When the oil becomes dirty, repeat steps 1
through 12.

VERTICAL UNITS (MODELS 200, 250, 300)

Upper Casing Half Removal:

WARNING: Falling Objects Hazard
Eyebolts or lifting lugs, if provided, are for

lifting only the components to which they are
attached. Failure to follow these instructions could
result in serious personal injury or death, or
property damage.

NOTE: If only the upper half casing is to be
removed for inspection of the rotating
element, it will not be necessary to remove
the line shafting or motor.

1. IMPORTANT: The rotating element

must be restrained to the lower half
casing or to the pedestal by means of
straps.

WARNING:
Injury may result due to rotating element

falling out of lower half casing if the above
procedure is not followed.