Section 5

Troubleshooting Guide

Turn off the power before servicing the pump.

A. PUMP WILL NOT START

B. MOTOR OVERHEATS AND THE OVERLOAD TRIPS OUT

Cause of Trouble

How to Check

How to Correct

1. Blown fuse.

Check to see if fuse is ok.

If blown, replace with fuse of proper

size, (see page 1).

2. Power off.

Try lights on same circuit.

Contact power company.

3. Loose, broken, or incorrect

wiring.

Remove plate. Check wiring circuit

against diagram. See that all

connections are tight and that no

short circuits exist because of worn

insulation, crossed wire, etc.

Rewire any incorrect circuits as per

wiring diagram.

4. Faulty pressure switch.

Check switch setting. Examine switch

contacts for dirt or excessive wear.

Adjust switch settings. Clean contacts

with emery cloth if dirty.

5. Tubing to pressure switch

plugged.

Remove tubing and blow through it.

Clean or replace if plugged.

6. Impeller or seal.

Use screwdriver to try to turn

impeller or motor.

If impeller will not turn, remove

housing and locate source of binding

or return pump.

7. Defective motor.

After checking steps 1 through 6

(and external wiring is ok) motor is

defective.

Return pump if still under warranty.

Cause of Trouble

How to Check

How to Correct

1. Motor wired incorrectly.

Check motor wiring diagram.

Reconnect for proper voltage as per

wiring diagram.

2. Inadequate ventilation.

Check air temperature where pump is

located. If over 100° F, overload may

be tripping on external heat.

Provide adequate ventilation or move

pump.

3. Prolonged low pressure

delivery.

(Such as sprinkler systems.)

Continuous operation at very low

pressure places heavy overload on

pump. This can cause overload

protection to trip.

Install Red Jacket Hydrovervant I

valve on discharge line and throttle

to reduce flow and increase pressure.

4. Incorrect line voltage.

Check line voltage to pressue switch.

If voltage is under recommended

minimum, check size of wiring from

main switch on property. If ok,

contact power company.