Description of equipment, Representative piping diagrams – Bell & Gossett DN0130D Domestic Pump 250°F Condensate Units Series SA-PT User Manual
Page 2

2
DESCRIPTION OF EQUIPMENT
The Series SA, and SA-P units consists of an ASME Code
stamped steel receiver (permitting operating under pressure up
to 15 psig [1.0 Bar] and equivalent temperature up to 250°F
[121°C]). Series B35 centrifugal pump(s) designed for 2 ft. (0.6M)
NPSH, corrosion inhibitor (anode), water level gauge, ther-
mometer, pressure relief valve, thermostatic air vent trap, com-
pound gauge, valve(s) in pump suction, and a drain (gate)
valve. Occasionally, Series SA units are fully vented; these
receivers feature ASME Code construction except the code
stamped is omitted. In addition to the above components, the
Series SA-P employs a proportioning regulator and valve (elec-
tric or pneumatic). The Series SA unit uses float switch controls.
Control panels and components supplied per specification.
When Series SA units are furnished with ASME Code stamped
receivers, relief valve and air vent trap to permit pressurization,
then the receiver inlet is directly connected to the outlet of the
steam absorption unit or other steam process equipment with-
out steam traps in the return line. When used in this manner, a
separate SA unit is usually required for each independently
controlled heating unit.
It is, however, possible to use a single SA unit with multiple
heating units. Detailed information and drawings will be fur-
nished on request.
The relief valve on the unit is set at 15 psi (1.0 Bar) and rated at
1900 pph (862 Kg/hr) steam. Any additional system protection
must be provided as required by others.
PRELIMINARY INSPECTION
Assure that there is no shipping damage.
Assure that nameplate ratings agree with job specifications and
actual conditions.
HANDLING
Use care in installing unit.
MECHANICAL DRAIN
VALVE (OPTIONAL)
FLOAT SWITCH
FOR STAND BY
THERMOSTATIC
VENT TRAP
TO DRAIN
PUMP
DISCHARGE
DOMESTIC SERIES B35
CENTRIFUGAL PUMP
(SERIES DB PUMP
OPT., SEE DETAIL AA)
GAUGE
GLASS
DIAL
TEMP.
GAUGE
ANODE
COMPOUND GAUGE
PROPORTIONING
REGULATOR
PRESSURE RELIEF VALVE,
PIPE TO DRAIN (PITCH DOWN)
STEAM
ABSORPTION UNIT
OR
CONVERTER
OR
FAN COIL UNIT
OR
STEAM PROCESS
EQUIPMENT
COMPOUND
GAUGE
GAUGE
GLASS
DIAL
TEMP.
GAUGE
DOMESTIC SERIES B35
CENTRIFUGAL PUMP
(SERIES DB PUMP
OPT., SEE DETAIL AA)
PUMP
DISCHARGE
TO DRAIN
ANODE
THERMOSTATIC
VENT TRAP
PRESSURE RELIEF VALVE
PIPE TO DRAIN (PITCH DOWN)
MECHANICAL DRAIN
VALVE (OPTIONAL)
FLOAT SWITCH
PUMP DISCHARGE
FLEXIBLE
PUMP
CONNECTOR
PUMP
SUCTION
LEGEND:
“Y” STRAINER
GATE VALVE
UNION
PLUG COCK
CHECK VALVE
NON SLAM
CHECK VALVE
FLANGE
PROPORTIONING
CONTROL VALVE
DETAIL AA
DETAIL OF RECOMMENDED PIPING TO
SERIES DB HIGH PRESSURE PUMP
1DPD22
1DPD32
High Temperature Condensate Units
Series SA and SA-P
REPRESENTATIVE PIPING DIAGRAMS
SERIES SA
SERIES SA-P