Dealer servicing, Pump service instructions for series b35 pumps – Bell & Gossett DN0130D Domestic Pump 250°F Condensate Units Series SA-PT User Manual

Page 7

Advertising
background image

7

DEALER SERVICING

If trouble occurs that cannot be rectified, contact your local

B&G representative. He will need the following information in

order to give you assistance.
1. Complete nameplate data of pump and motor. SEE RATING

NAMEPLATE.

2. Suction and discharge pipe pressure gauge readings.
3. Ampere draw of the motor.
4. A sketch of the pump hook-up and piping.

1. Close pump isolation valve or system return line valve.

Operate pump momentarily to discharge as much water as

possible. Close pump discharge valve.

2. Shut-off and lock out power.

3. Make sure unit is cool enough that pump can be handled

safely. Open drain to remove remaining liquid.

4. Carefully remove pump drain plug and bleed line. Wait for

complete drainage.

5. Loosen both the discharge connection and the suction

housing to pump volute fasteners. Assure that pressure is

relieved per caution note.

6. Complete the removal of the above hardware. Remove

pump/motor assembly and place on work bench.

7a. Remove the suction housing capscrews and separate the

pump/motor assembly from the suction housing. Note, the

diffuser should separate from the suction housing to allow

the pump/motor assembly to be removed.

7b. Remove propeller, propeller stem and diffuser from the

assembly as follows:
(1) Threaded Motor Shafts (3Hp and less). Remove pro-

peller lock nut. Remove propeller with propeller stem as

an assembly with the diffuser. To install a new propeller,

remove the propeller set screws and separate from the

stem.

(2) Keyed Motor Shafts (5Hp and larger). Remove propeller

set screws. Remove propeller, remove diffuser, and

unscrew the propeller stem.

Morton Grove, Illinois 60053

TM

TM

SERIES

MODEL

SERIAL

GPM

PSI

PUMP

CFM

IN HG.

PUMP

DWGS

POWER V.

PH.

HZ60

CONTROL V.

PH. 1

HZ60

TOTAL

LARGEST MOTOR

F.L. AMP

F.L. AMP

DN0016

PUMP SERVICE INSTRUCTIONS FOR SERIES B35 PUMPS

AS USED ON SA & SA-P UNITS

CAUTION: PRESSURIZED SYSTEM

Operating system may contain very hot water and

steam under pressure. Close inlet and open drains before

servicing. When servicing, loosen screws and move compo-

nents to assure pressure is relieved before removing screws.

Keep drains open during servicing. Failure to follow these

instructions could result in injury or property damage.

CAUTION: HOT SURFACES

Surfaces are hot when system is in operation. Do not

touch hot receiver, let unit cool before servicing. Failure to

follow these instructions could result in serious injury or

death.

WARNING: HIGH VOLTAGE

Disconnect and lock out power before connecting or

servicing unit. Failure to follow these instructions could

result in serious injury or death.

HEAVY DUTY

BALL BEARING MOTOR

WATER SLINGER

MECHANICAL SEAL

STAINLESS STEEL SHAFT
MOTOR BRACKET
PUMP VOLUTE W/WEAR RING
IMPELLER

IMPELLER

AXIAL FLOW PROPELLER

PROPELLER SET SCREW

SUCTION HOUSING

Advertising
This manual is related to the following products: