Î

CHANGING ROT

ATION

Series HSCS centrifugal pumps can be operated left hand or

right hand when viewed from the pump end of the pump. If
you wish to reverse the suction and discharge nozzles, this
can be accomplished with the same pump as follows:

IMPOR

TANT:

Refer to the disassembly and assembly pr

oce-

dures section of this manual for proper disassembly and
assembly techniques:

1. Remove the impeller from the shaft, turn it 180° and replace

it on the shaft. (Follow the disassembly procedures given in
this manual.)

2. With the rotating element out of the casing, remove the

casing from the bedplate and turn 180°.

3. Set the rotating element back in the casing and reassemble

the pump.

NOTE: The impeller and casing ar

e in the same relationship

to each other as they were originally. The shaft and motor
are also in the same relationship to each other as they were
originally.

4. Reassemble pump and realign the coupling as called for in

the alignment instructions.

5. The rotation of the motor must be changed by switching the

motor leads.

NOTE: Unless the motor r

otation is reversed, the impeller

will run backward.

W

ARNING: Rotating Components Hazard

Do not operate pump without all guar

ds in place.

Failure to follow these instructions could result in serious
personal injury or death and property damage.

ROTATION

ROTATION

DISCHARGE

DISCHARGE

SUCTION

CLOCKWISE ROTATION VIEWED

FROM THE COUPLING END

COUNTER-CLOCKWISE ROTATION VIEWED

FROM THE COUPLING END

FIGURE 9 – CORRECT RELA

TIONSHIP OF IMPELLER AND CASING