DISMANTLING (PUMP WITH MECHANICAL SEALS

ON SHAFT SLEEVES)

CAUTION: Extreme Temperature Hazard

Allow pump temperatur

es to reach acceptable levels

before proceeding. Open drain valve. Do not proceed until
liquid stops coming out of drain valve. If liquid does not
stop flowing from drain valve, isolation valves are not
sealing and should be repaired before proceeding. After
liquid stops flowing from drain valve, leave drain valve
open and continue. Remove the drain plug located on the
bottom of the pump housing. Do not reinstall plug or close
drain valve until reassembly is completed. Failure to follow
these instructions could result in property damage and/or
moderate personal injury.

W

ARNING: Unexpected Startup Hazard

Disconnect and lockout power befor

e servicing.

Failure to follow these instructions could result in serious
personal injury or death, or property damage.

W

ARNING:

Prior to working on pump the power

source should be disconnected with lockout provi-

sions so power cannot be re-energized to the motor. Close
isolating suction and discharge valves. Failure to follow
these instructions could result in property damage, severe
personal injury, or death.

TABLE “A”

Pump Size

Qty.

Dimension A

2-904-9

8x12x22M

26

13.50

8x12x22L

26

10x14x20S

26

12x16x23

26

15.81

14x16x17

24

14x18x23

32

10x14x20L

26

16.60

FIGURE

19 – ASSEMBLY SECTION: PUMP WITH PACKING

15.81

W

ARNING: Electrical Shock Hazard

Electrical connections to be made by a qualified

electrician in accordance will all applicable codes, ordi-
nances, and good practices. Failure to follow these
instructions could result in serious personal injury or death,
or property damage.