Xylem AC8584C Series HSCS Base Mounted Centrifugal Pumps User Manual

Page 24

Advertising
background image

2

(See Appendix “A” for exploded view.)

Ê

1. Close valves on suction and discharge sides of pump. If

Ê

no valves have been installed, it will be necessary to drain

Ê

the system.

Ê

2. Remove the coupler guard. Refer to section titled “Hex

Ê

Coupler Guard Removal/Installation.

Ê

3. Loosen the capscrews which secure the coupler flanges

Ê

to the coupler hubs. Remove the coupler flanges and

Ê

sleeve by compressing the flanges and pulling out from

Ê

beneath the hubs or by loosening the allen set screws and

Ê

sliding the hubs back on the shafts. Remove the coupler

Ê

hub from the pump shaft.

Ê

4. Drain the pump by opening vent plug (0-910-0) and

Ê

remove drain plugs (0-910-0) on suction and discharge

Ê

nozzle.

Ê

5. Remove seal lines (0-901-0, 0-950-0, 0-952-0), if supplied.

Ê

6. Remove gland bolts (3-904-9) and slide gland (3-014-2)

Ê

away from casing.

Ê

7. Remove all casing main joint cap screws (2-904-1) and

Ê

dowels (2-916-9). Use slot in casing main joint and sepa-

Ê

rate the casing halves with a pry bar. Lift upper half casing

Ê

(2-001-7) by cast lugs.

Ê

8. Remove cap screws (1-904-9) which hold bearing

Ê

housings (3-025-2) to the casing and lift rotating element

Ê

out of lower casing (2-001-08). Rotating element may now

Ê

be moved to a suitable working location.

Ê

9. Pull coupling half and key (3-911-2) off shaft (3-007-0).

Ê

NOTE: A spar

e rotating element can be installed at this

Ê

point.

Ê

10. Remove cap screws (3-904-9) from bearing covers (3-018-3,

К

-4).

К

11. Remove bearing housings (3-025-2), locknut (3-516-4),

Ê

and lockwasher (3-517-4). Mount bearing puller and

Ê

remove bearings (3-026-2). Remove thrust washer (3-078-9)

Ê

and snap ring (3-915-9).

Ê

NOTE: Locknut, lockwasher

, and thrust washer are not

Ê

used on inboard side.

12. Remove bearing covers (3-018-5, -4) and push oil seals

Ê

(3-177-9) out of bearing covers and coupling and bearing

Ê

housing. Pull deflectors (3-136-9) off shaft.

Ê

13. Remove glands (3-014-2). Loosen set screws and remove

Ê

mechanical seal head assembly (3-402-0). Press mechan

Ê

ical seal seats (3-401-0) from glands.

Ê

14. Remove casing rings (3-003-9) from impellers (4-002-0).

Ê

15. Remove set screw (3-902-9) from shaft nuts. Remove

Ê

shaft nuts (3-015-9), O-rings (3-914-9), sleeves (3-009-9),

Ê

sleeve gaskets (1-428-1), and impeller (4-002-0).

Ê

NOTE: Apply heat uniformly to the shaft sleeve to loosenÊ

the sealant between the shaft and sleeve.

Ê

To further assist in removing the sleeves, hold the shaft

Ê

vertically and drop it on a block of wood. The impeller

Ê

weight should force both the impeller and sleeve from the

Ê

shaft.

Ê

16. Refer to page 26 if pump is equipped with adjustable

Ê

rings.

Ê

NOTE: For impellers with r

eplaceable rings - remove the

Ê

rings (4-004-9) by cutting the rings with a cold chisel. (See

Ê

Figure 20)

Ê

FIGURE 20 – CASING AND IMPELLER RINGS

CAUTION:

DO NOT REUSE THE BALL BEARINGS.

Ê

CAUTION:
DO NOT EXCEED 275ºF

.

К

Advertising