SAFETY INSTRUCTIONS

TO AVOID SERIOUS OR FATAL PERSONAL INJURY

OR MAJOR PROPERTY DAMAGE, READ AND

FOLLOW ALL SAFETY INSTRUCTIONS IN MANUAL

AND ON PUMP.
THIS MANUAL IS INTENDED TO ASSIST IN THE

INSTALLATION AND OPERATION OF THIS UNIT

AND MUST BE KEPT WITH THE PUMP.

This is a SAFETY ALERT SYMBOL.

When you see this symbol on the pump

or in the manual, look for one of the fol-

lowing signal words and be alert to the

potential for personal injury or property

damage.
Warns of hazards that WILL cause

serious personal injury, death or major

property damage.
Warns of hazards that CAN cause

serious personal injury, death or major

property damage.
Warns of hazards that CAN cause per-

sonal injury or property damage.

NOTICE: INDICATES SPECIAL INSTRUCTIONS

WHICH ARE VERY IMPORTANT AND

MUST BE FOLLOWED.

THOROUGHLY REVIEW ALL INSTRUCTIONS

AND WARNINGS PRIOR TO PERFORMING ANY

WORK ON THIS PUMP.
MAINTAIN ALL SAFETY DECALS.

UNIT NOT DESIGNED FOR USE

WITH HAZARDOUS LIQUIDS OR

FLAMMABLE GASES. THESE

FLUIDS MAY BE PRESENT IN

CONTAINMENT AREAS.

DESCRIPTION and SPECIFICATIONS:

The Model HSC is a multi-stage, end-suction, centrifugal

pump for general liquid transfer service, booster applica-

tions, etc. Liquid-end construction is cast iron, stainless

steel and engineered composites.
All units have NEMA 48 Frame single-phase, 115/230

V, 60 Hz motors with C-face mounting and NEMA 56J

threaded shaft extensions.

1. IMPORTANT

1.1. Inspect unit for damage. Report any damage to car-

rier/dealer immediately.

1.2. Electrical supply must be a separate branch circuit

with fuses or circuit breakers, wire sizes, etc., in

compliance with National and Local electrical codes.

Install an all-leg disconnect switch near pump.

ALWAYS DISCONNECT ELECTRICAL

POWER WHEN HANDLING PUMP OR

CONTROLS.

1.3. Motors must be wired for proper voltage. Motor

wiring diagram is on motor nameplate. Wire size

must limit maximum voltage drop to 10% of name-

plate voltage at motor terminals, or motor life and

pump performance will be lowered.

1.4. Always use horsepower-rated switches, contactor and

starters.

1.5. Motor Protection

1.5.1. Single phase: Thermal protection for single

phase units is sometimes built in (check name-

plate). If no built-in protection is provided, use

a contactor with a proper overload. Fusing is

permissible.

1.6 Maximum Operating Limits:

Liquid Temperature: 180°F (82°C)

Working Pressure:

125 PSI

Starts per Hour:

20, evenly distributed.

1.7 Regular inspection and maintenance will increase

service life. Base schedule on operating time.

2. INSTALLATION

2.1. Locate pump as near liquid source as possible (below

level of liquid for automatic operation).

2.2. Protect from freezing or flooding.
2.3. Allow adequate space for servicing and ventilation.
2.4. All piping must be supported independently of the

pump, and must “line-up” naturally.

NEVER DRAW PIPING INTO PLACE BY

FORCING THE PUMP SUCTION AND

DISCHARGE CONNECTIONS.

2.5. Avoid unnecessary fittings. Select sizes to keep fric-

tion losses to a minimum.

2.6. Units may be installed horizontally, inclined or verti-

cally.

DO NOT INSTALL WITH MOTOR BE-

LOW PUMP. ANY LEAKAGE OR CON-

DENSATION WILL AFFECT THE MOTOR.

Figure 1

Figure 3

1.5D

min.

3.0D

min.

D

D

H min.

D

min.

2

---------

---------

D

H min.

Figure 2

D

H min.

---------

---------

Figure 4

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

H

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

V

H

=

Min.

Submergence

in

feet

V = Velocity in feet per second

=GPM x 0.321 GPM x 0.4085

Area D

2